1.
Materials (Basel) ; 17(6)2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38541567

RESUMEN

This study aimed to evaluate the effect of two coating materials, a silicone sealing gel and a polytetrafluoroethylene (PTFE) tape, on the screw preload and removal torque value (RTV) to develop strategies to prevent prosthetic screw loosening. We examined 45 complexes comprising an implant, abutment, and prosthetic screw, of which 15 samples were uncoated, 15 were coated with GapSeal® (Hager & Werken GmbH & Co., Duisburg, Germany), and 15 were coated with PTFE tape (MIARCO®, Valencia, Spain). The screws were tightened to register the preload and then untightened to register the RTV. The preload values showed a statistically significant difference only in the PTFE group, suggesting that this lubricant negatively affects the preload. The RTVs showed statistically significant differences among all groups, with the GapSeal® group and PTFE group showing the highest and lowest values, respectively. It can be concluded that the application of the PTFE tape on the screw significantly reduced the preload and RTV. The silicone sealing gel did not affect the preload but increased the RTV. Therefore, the use of GapSeal® should be considered to prevent prosthetic screw loosening, while the use of PTFE tape should be avoided.

2.
Materials (Basel) ; 17(2)2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38255602

RESUMEN

STATEMENT OF PROBLEM: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests. OBJECTIVE: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests. MATERIALS AND METHODS: Four KLOCKNER implants (external connection SK2 and KL; and internal connection VEGA and ESSENTIAL) were submitted to three different mechanical requests: single tightening, multiple tightening, and multiple tightening and cyclic loading (500 N × 100 cycles). A total of 16 samples were evaluated by SEM, by the X-ray Bragg-Brentano method to obtain residual stresses, and scratch tests were realized for each surface and Micro-CT (4 control samples; 4 single tightening; 4 multiple tightening; 4 multiple tightening and cyclic loading). All dental implants were fabricated with commercially pure titanium (grade 3 titanium). Surface topography and axial displacement of abutment into the implant, from each group, were evaluated by SEM and Micro-CT. RESULTS: In the manufacturing state, implants and abutments revealed minor structural changes and minimal damage from the machining process. The application of the tightening torque and loading was decisive in the appearance and increase in contact marks on the faces of the hexagon of the abutment and the implant. Vega has the maximum compressive residual stress and, as a consequence, higher scratch force. The abutment-implant distances in SK2 and KL samples did not show statistically significant differences, for any of the mechanical demands analyzed. In contrast, statistically significant differences were observed in abutment-implant distance in the internal connection implants Vega and Essential. CONCLUSIONS: The application of mechanical compression loads caused deformation and contact marks in all models tested. Only internal connection implants revealed an axial displacement of the abutment into the implant, but at a general level, a clear intrusion of the abutment into the implant could only be confirmed in the Essential model, which obtained its maximal axial displacement with cyclic loading.

3.
Polymers (Basel) ; 15(16)2023 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-37631468

RESUMEN

Implant-supported provisional restorations are critical for improving the esthetics and shaping of the peri-implant tissue. The mechanical properties of these provisional materials can be influenced by saliva, food, beverages, and interactions between these materials in the oral environment. Therefore, the integrity of provisional restorations should be preserved throughout the treatment period. This study aimed to evaluate the fracture strength of implant-supported polymethyl methacrylate (PMMA) provisional restorations made of computer-aided design and computer-aided manufacturing when immersed in different solutions at a controlled temperature of 37 °C for 7 days. Each analog-pillar-crown set was submerged in different liquids: 10 pieces were placed in distilled water then in tea, coffee, red wine, and Coca Cola® for 1 week at a controlled oral temperature of 37 °C. The samples were then subjected to fracture forces. The moment of fracture of the crown was recorded and compared with those of the other samples. Specimens immersed in distilled water (control group) had the highest fracture resistance (mean [M] = 1331.00 ± 296.74 N), while those immersed in tea had the lowest mean resistance to fracture (mean [M] = 967.00 ± 281.86 N). Nutritional deficiency and inappropriate eating habits influence the fracture strength of temporary crowns, thereby rendering them more elastic or less resistant to fractures.

4.
Biomedicines ; 11(6)2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37371776

RESUMEN

Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration and loss of retention of overdenture attachments in a 12-month clinical-use simulation. In this way, ten specimens each of different brands of retentive caps made of Teflon (OT Equator® (Rhein83, Bologna, Italy), Locator® (Zest Anchors, Escondido, CA, USA), Kerator® (KJ Meditech, Gwangiu, Republic of Korea), and Locator R-Tx® (Zest Anchors, Escondido, CA, USA)) were immersed in five different cleaning solutions (Kukident® (P&G Tech, Oxford Parkway, UK), Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain), Corega® (Stafford Miller, Waterford, Ireland), and Protefix® (Neuhofer Weiche, Parchim, Germany)), and tap water was used as the control group, in a simulation that lasted 12 months. Data were analyzed using two-way ANOVA and a Tukey HSD. Furthermore, a Levene Test and Shapiro-Wilk tests were performed to assess the validation of the ANOVA assumptions. The statistical analysis was performed using R version 4.2.2 software with the significance level set to p < 0.05. There were significant statistical differences between the different manufacturers regarding the retention forces of the attachment's retentive caps (F = 322.066, p < 0.001). For the cleaning solution groups, different statistical results between Kukident® (P&G Tech, Oxford Parkway, UK) (p < 0.05) and Benfix® (Laboratorios URGO S.L., Guipúzcoa, Spain) (p < 0.05) were observed. There were no significant statistical differences between Corega® (Stafford Miller, Ireland), Protefix® (Neuhofer Weiche, Parchim, Germany), and tap water, even though the retention forces decreased in all of them.

5.
Materials (Basel) ; 15(19)2022 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-36233980

RESUMEN

(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia's fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional "load-to-failure" test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.

6.
Artículo en Inglés | MEDLINE | ID: mdl-36293951

RESUMEN

Forensic dentistry plays an important role in human identification, and dental age estimation is an important part of the process. Secondary dentin deposition throughout an individual's lifetime and consequent modification in teeth anatomy is an important parameter for age estimation procedures. The aim of the present study was to develop regression equations to determine age in adults by means of linear measurements and ratios on sagittal, coronal and axial slices of maxillary central incisors using cone bean computed tomography (CBCT). Multiplanar measurements of upper central incisors were taken for a sample of 373 CBCTs. Subsequently, one-way analysis of variance (ANOVA) and multivariate linear regressions were performed for age estimation. The equations obtained from axial linear measurements and ratios presented a standard error of the estimate (SEE) of ±10.9 years (R2 = 0.49), and a SEE of ±10.8 years (R2 = 0.50), respectively. The equation obtained for multiplanar linear measurements presented a SEE of ±10.9 years (R2 = 0.52), while the equation for multiplanar ratios presented a SEE of ±10.7 years (R2 = 0.51). Thus, CBCT measurements on upper central incisors were found to be an acceptable method for age estimation. Horizontal measurements, especially pulp measurements, improve the accuracy of age estimate equations.


Asunto(s)
Determinación de la Edad por los Dientes , Dentina Secundaria , Adulto , Humanos , Incisivo/diagnóstico por imagen , Determinación de la Edad por los Dientes/métodos , Tomografía Computarizada de Haz Cónico/métodos , Odontología Forense/métodos
7.
Polymers (Basel) ; 14(9)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35566919

RESUMEN

(1) Introduction: Denture adhesives (DAs) promote stability, chewing ability, and quality of life. The objective of this study was to compare the effectiveness of original brand DAs and white brands in their retention of conventional complete dentures. (2) Methods: This study followed the recommendations of the international standard ISO 10873. Three original brands of DA (Corega® Fixação 3D, GlaxoSmithKline®, Stafford Miller Ltd., Dungarvan Co. Waterford, Ireland), KuKident® Pro Procter & Gamble Technical Centres®, Ltd., Whitehal Lane, Germany and Elgydium® Fix, Laboratórios URGO® SL, Florida, Spain) were compared to three white brands (Fixação Extra Forte Pingo Doce®, Laboratórios Cosmodent®, Cantabria, Spain), Fixador de Próteses (Continente®, Propack®,Gmbh, Ladenburg, Germany) and Creme Fixador de Próteses (Auchan®, Ellipse®, Roubaix, France). Their retention capacities were analyzed using a mechanical test device. (3) Results: The mean retentive ability of original brand adhesives (M = 11.16, SD = 5.27) was significantly higher (t(298) = 11.88; p < 0.001) than that of the white brands (M = 5.92, SD = 1.18). When comparing all brands, statistically significant differences were also observed, F(5.294) = 707.68 (p < 0.001). The generic adhesive results were more homogeneous. The generic brands from Continente® (M = 5.24, SD = 0.94) and Auchan® (M = 5.80, SD = 0.79) were not significantly different, while the Pingo Doce® brand obtained significantly higher mean retention results (M = 6.71, SD = 1.28). (4) Conclusions: The original brands of DA have a significantly higher retentive ability than the white brands. Elygidim® Fix had the worst result of the three original brands, and the product from Pingo Doce® had the best result among the three white brands.

8.
Materials (Basel) ; 15(4)2022 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-35207933

RESUMEN

The stability and integrity of the abutment-implant connection, by means of a screw, is fallible from the moment the prosthetic elements are joined and is dependent on the applied preload, wear of the components and function. One of the main causes of screw loosening is the loss of preload. The loosening of the screw-abutment can cause complications such as screw fracture, marginal gap, peri-implantitis, bacterial microleakage, loosening of the crown and discomfort of the patient. It is also reported that loosening of the screw/abutment may lead to a failure of osseointegration. It is necessary to evaluate and quantify, with in vitro studies, the torque loss before and after loading in the different connections. Aim: evaluate the influence of implant- abutment connection design in torque maintenance after single tightening, multiple tightening and multiple tightening followed by mechanical cycling. Materials and Methods: 180 Klockner implants divided in 4 groups: 15 SK2 external connection, 25 Ncm tightening torque; 15 KL external connection, 30 Ncm tightening torque; 15 Vega internal connection, 25 Ncm tightening torque; 15 Essential internal connection, 30 Ncm tightening torque. In each group removal torque values (RTV) were evaluated with a digital torque meter, in 3 distinct phases: after one single tightening, 10 multiple tightenings and 10 multiple tightenings and cyclic loading (500 N × 1000 cycles). Results: After one single tightening, and for all connections, RTV were lower than those of insertion, but only for Essential and Vega internal connections this result was statistically significant. After multiple tightening, RTV were significantly lower in all connections. After repeated tightening followed by cyclic loading, mean RTV were significantly lower, when compared to insertion torque. The multiple tightening technique resulted in higher RTV than the single tightening technique, except for Vega implant. The multiple tightening followed by cyclic load, compared to the other phases, was the one that generated the lowest RTV, for all connections. Conclusions: The connection design, in our study, did not seem to influence the maintenance of preload. Loading influenced the loss of preload, in the sense that significantly decreased the removal torque values. The multiple re-tightening technique resulted in higher removal torque values than the single tightening technique. Clinically, our results recommend to retighten retaining screws, a few minutes after insertion.

9.
Int J Dent ; 2021: 5133556, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34899914

RESUMEN

Micromovements of the implant-abutment connection influence peri-implant bone preservation. The maximal torque after a cycle of implant prosthetic screw tightening using original components of different manufacturers and replicas produced by other companies is evaluated and quantified in this study. A total of 30 Mis Seven® standard platform implants and 30 interfaces were used, and 30 standard platform screws were tested, 10 Mis®, 10 Iconekt®, and 10 Exaktus®. The screws were tightened with an MIS® torquemeter until their respective fracture, and the fracture point was measured through the equipment's load cell, CS-Dental Testing Machine®. The screws were analyzed under an Olympus® SZ61 microscope. The fracture points were recorded and compared among all samples. To compare the mean values of the fracture torques, t-tests were performed using the reference values associated with each brand and the sample results. The variable "Place of Fracture" between the original Mis® brand and the Exaktus® replica compared to the Iconekt® replica presented a statistically significant difference (p < 0.001). When analyzing the variable "Fracture Torque," although it was verified that the replica screws (Iconekt® and Exaktus®) had a lower maximum torque, 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis® brand (70 Nm and 69 Nm), there were no statistically significant differences p > 0.05. Nonoriginal screws did not present different fracture resistances compared to the original Mis® brand screws. The fracture site of Iconekt® screws showed a different pattern compared to the other brands.

10.
Polymers (Basel) ; 13(8)2021 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-33920377

RESUMEN

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.

11.
Int J Dent ; 2020: 8941876, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33204269

RESUMEN

METHODS: Ten prosthesis bases prepared with each brand of resin were subjected to neutral and low pH conditions (pH 7 and pH 4) by submerging them in artificial saliva for 30 days. After exposure, the fatigue resistance of the resins was tested using a Dental CS® Testing Machine. Statistical Analysis Test. The data sets were described quantitatively in terms of mean (M) and standard deviation (SD). Shapiro-Wilk tests and unilateral analysis of variance (ANOVA) were performed and complemented by Tukey's multiple comparison tests. The effect size (η2), whose cohort points followed Cohen's recommendations: 0.01 (low), 0.06 (medium), and 0.14 (high), was calculated. The results were considered significant if p < 0.05 and marginally significant if p < 0.10. RESULTS: One-way ANOVA showed that Megacryl® had the highest fracture resistance at pH 7 (52.23 Kgf), compared with Triplex Hot® (p < 0.001) and RS Vertex® (p=0.034). Two-way ANOVA confirmed the interaction between brand and pH (p=0.022), also revealing that brands comparison is significant or marginally significant, when pH is not considered (Megacryl® versus Triplex Hot®, p < 0.001, and RS Vertex®, p=0.058; Triplex Hot® versus RS Vertex®, p=0.051), and pH 7 results were significantly higher (p=0.003), even when brands are not considered. Hence, Megacryl® at pH 7 was found to have the highest fracture resistance, detached from other brands and pH values. CONCLUSION: It can be concluded within the limitations of this study that there are differences in the fracture resistance among the three brands of acrylic resin. Megacryl® was found to have the highest fracture resistance, and Triplex Hot® was the lowest. The results also show that exposure to a low pH environment decreases the fracture resistance of the Megacryl® and RS Vertex® resins.

12.
Artículo en Inglés | MEDLINE | ID: mdl-33238476

RESUMEN

Introduction: Different implant-abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant-abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant-abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment-implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.


Asunto(s)
Tornillos Óseos , Fenómenos Biomecánicos , Bases de Datos Factuales , Torque
13.
Dent J (Basel) ; 8(4)2020 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-33050156

RESUMEN

Micromovements of the implant-abutment connection influence peri-implant bone preservation. This study evaluates and quantifies the maximal torque after a cycle of implant prosthetic screws tightening using original components. A total of 40 samples were tested: Megagen®-Daegu, South Korea; Dentium®-Gangnam-Gu, Seoul, Korea; BIOMET 3i®-West Palm Beach, FL, USA and BTI®-Álava, Spain. Screws from each manufacturer were subjected to maximal stress force until they fractured. The fracture points were recorded and compared among all samples. To compare the mean values of fracture torques, the reference values associated with each brand and the sample results were used in t-tests. ANOVA (analysis of variance) was used to compare the maximal resistance limit between brands, complemented with Tukey's multiple-comparison test. The maximal considered level of significance was 5%. The average fracture force for the brands was 40.07 Ncm for Megagen®, 53.39 Ncm for Dentium®, 39.74 Ncm for Biomet 3i®, and 68.84 Ncm for BTI®. BTI® screws showed the most resistance to fracture. According to the protocol that was applied, the implant-abutment connection demonstrated good resistance and a precise fit between these interfaces; therefore, in some cases, the presented values showed a lack of quality control and low fracture resistance.

14.
J Adv Prosthodont ; 8(1): 21-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26949484

RESUMEN

PURPOSE: This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS: Three commercially available attachments were investigated: Clix®, Dalbo-Plus® and Locator®. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37℃. The abutments were placed at angulations of 0°, 10° and 20°. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS: The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION: Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

15.
J Adv Prosthodont ; 7(1): 32-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25722835

RESUMEN

PURPOSE: The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS: Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at 37℃ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS: The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION: More acidic pH values were found to have a negative influence on the retention capacity of the attachments.